Cooling load forecasting-based predictive optimisation for chiller plants
Extensive electric power is required to maintain indoor thermal comfort using heating, ventilation and air conditioning (HVAC) systems, of which, water-cooled chiller plants consume more than 50% of the total electric power. To improve energy efficiency, supervisory optimisation control can be adopted. The controlled variables are usually optimised according to instant building cooling load and ambient wet bulb air temperature at regular time intervals. In this way, the energy efficiency of chiller plants has been improved. However, with an inherent assumption that the instant building cooling load and ambient wet bulb temperature remain constant in the coming time interval, the energy efficiency potential has not been fully realised, especially when cooling loads vary suddenly and extremely. To solve this problem, a cooling load forecasting-based predictive optimisation method is proposed. Instead of minimising the instant system power according to the instant building cooling load and ambient wet bulb temperature, the controlled variables are derived to minimise the sum of the instant system power and one-time-step-ahead future system power according to both instant and forecasted future building cooling loads. With this method, the energy efficiency potential of a chiller plant can be further improved without shortening the operation time interval. 80% redundant energy consumption has been reduced for the sample chiller plant; energy can be saved for chiller plants that work for years. The evaluation on the effect of cooling load forecasting accuracy turns out that the more accurate the forecasts are, the more redundant energy consumption can be reduced
A simple statistical model for prediction of acute coronary syndrome in chest pain patients in the emergency department
BACKGROUND: Several models for prediction of acute coronary syndrome (ACS) among chest pain patients in the emergency department (ED) have been presented, but many models predict only the likelihood of acute myocardial infarction, or include a large number of variables, which make them less than optimal for implementation at a busy ED. We report here a simple statistical model for ACS prediction that could be used in routine care at a busy ED. METHODS: Multivariable analysis and logistic regression were used on data from 634 ED visits for chest pain. Only data immediately available at patient presentation were used. To make ACS prediction stable and the model useful for personnel inexperienced in electrocardiogram (ECG) reading, simple ECG data suitable for computerized reading were included. RESULTS: Besides ECG, eight variables were found to be important for ACS prediction, and included in the model: age, chest discomfort at presentation, symptom duration and previous hypertension, angina pectoris, AMI, congestive heart failure or PCI/CABG. At an ACS prevalence of 21% and a set sensitivity of 95%, the negative predictive value of the model was 96%. CONCLUSION: The present prediction model, combined with the clinical judgment of ED personnel, could be useful for the early discharge of chest pain patients in populations with a low prevalence of ACS
Three little pieces for computer and relativity
Numerical relativity has made big strides over the last decade. A number of
problems that have plagued the field for years have now been mostly solved.
This progress has transformed numerical relativity into a powerful tool to
explore fundamental problems in physics and astrophysics, and I present here
three representative examples. These "three little pieces" reflect a personal
choice and describe work that I am particularly familiar with. However, many
more examples could be made.Comment: 42 pages, 11 figures. Plenary talk at "Relativity and Gravitation:
100 Years after Einstein in Prague", June 25 - 29, 2012, Prague, Czech
Republic. To appear in the Proceedings (Edition Open Access). Collects
results appeared in journal articles [72,73, 122-124
sFlt Multivalent Conjugates Inhibit Angiogenesis and Improve Half-Life In Vivo
We would like to thank Jonathan Winger and Xiao Zhu for guidance with the insect cell protein expression system and providing reagents. We would like to acknowledge Ann Fischer for help with expressing the sFlt protein in the Tissue Culture Facility at UC Berkeley and Dawn Spelke and Anusuya Ramasubramanian for help optimizing protein purification from insect cells. We are also grateful for the help from Leah Byrne and John Flannery at in the Helen Wills Neuroscience Institute at UC Berkeley for aiding us in the development of the rat intravitreal residence time model and for allowing us to use their facilities.Current anti-VEGF drugs for patients with diabetic retinopathy suffer from short residence time in the vitreous of the eye. In order to maintain biologically effective doses of drug for inhibiting retinal neovascularization, patients are required to receive regular monthly injections of drug, which often results in low patient compliance and progression of the disease. To improve the intravitreal residence time of anti-VEGF drugs, we have synthesized multivalent bioconjugates of an anti-VEGF protein, soluble fms-like tyrosine kinase-1 (sFlt) that is covalently grafted to chains of hyaluronic acid (HyA), conjugates that are termed mvsFlt. Using a mouse corneal angiogenesis assay, we demonstrate that covalent conjugation to HyA chains does not decrease the bioactivity of sFlt and that mvsFlt is equivalent to sFlt at inhibiting corneal angiogenesis. In a rat vitreous model, we observed that mvsFlt had significantly increased intravitreal residence time compared to the unconjugated sFlt after 2 days. The calculated intravitreal half-lives for sFlt and mvsFlt were 3.3 and 35 hours, respectively. Furthermore, we show that mvsFlt is more effective than the unconjugated form at inhibiting retinal neovascularization in an oxygen-induced retinopathy model, an effect that is most likely due to the longer half-life of mvsFlt in the vitreous. Taken together, our results indicate that conjugation of sFlt to HyA does not affect its affinity for VEGF and this conjugation significantly improves drug half-life. These in vivo results suggest that our strategy of multivalent conjugation could substantially improve upon drug half-life, and thus the efficacy of currently available drugs that are used in diseases such as diabetic retinopathy, thereby improving patient quality of life.Yeshttp://www.plosone.org/static/editorial#pee
An integrated model for the design of air-cooled chiller plants for commercial buildings
Cooling load calculation is the first step in designing the air-conditioning system of a building. The calculated
cooling capacity with appropriate buffer is then used to select the number and size of chillers in the
system. Nþ 1 is a common formula used by designers to size the chiller plants in Hong Kong buildings,
where N is the actual number of chillers required and 1 is a redundant chiller provided to ensure reliability.
This paper reviews the problem of excess capacity and discusses the risk exposure of chiller systems
without redundant chillers. The cooling load profiles of the chiller plants of four medium-sized commercial
buildings inHong Kongare reviewed. The risk exposure of chiller systemswithout redundant chillers can be
minimized byapplying risk-based preventive maintenance. The just-in-demand design reduces capital cost
of the building and frees up funds for continuous energy measurement and improving the energy efficiency
of chiller plant systems. This paper presents a model for designing chiller plants that improves the energy
efficiency of the plant in a cost effective and thoughtful manner. It is designed with consideration of the life
cycle of the plant and real-time continuous commissioning, monitoring, measurement, comparison and
execution for better energy manageme
Modeling study of design flow rates for cascade water supply systems in residential skyscrapers
202012 bcrcVersion of RecordPublishe
Environmental evaluation of pump replacement period in water supply systems of buildings
202311 bckwAccepted ManuscriptRGCPublishedGreen (AAM
Performance impact of indoor environmental policy implementation for airside systems in Hong Kong Grade A offices
2014-2015 > Academic research: refereed > Publication in refereed journalAccepted ManuscriptOthersThe Hong Kong Polytechnic University (GYX1Y, GYL19)Environment and conservation Fund (ECF) project 14/2013 from The HKSAR governmentPublishe
Recommended from our members
Cooling load forecasting-based predictive optimisation for chiller plants
Extensive electric power is required to maintain indoor thermal comfort using heating, ventilation and air conditioning (HVAC) systems, of which, water-cooled chiller plants consume more than 50% of the total electric power. To improve energy efficiency, supervisory optimisation control can be adopted. The controlled variables are usually optimised according to instant building cooling load and ambient wet bulb air temperature at regular time intervals. In this way, the energy efficiency of chiller plants has been improved. However, with an inherent assumption that the instant building cooling load and ambient wet bulb temperature remain constant in the coming time interval, the energy efficiency potential has not been fully realised, especially when cooling loads vary suddenly and extremely. To solve this problem, a cooling load forecasting-based predictive optimisation method is proposed. Instead of minimising the instant system power according to the instant building cooling load and ambient wet bulb temperature, the controlled variables are derived to minimise the sum of the instant system power and one-time-step-ahead future system power according to both instant and forecasted future building cooling loads. With this method, the energy efficiency potential of a chiller plant can be further improved without shortening the operation time interval. 80% redundant energy consumption has been reduced for the sample chiller plant; energy can be saved for chiller plants that work for years. The evaluation on the effect of cooling load forecasting accuracy turns out that the more accurate the forecasts are, the more redundant energy consumption can be reduced
Student learning performance and indoor environmental quality (IEQ) in air-conditioned university teaching rooms